VIDEO: Integrating Allen Bradley Micro800 to Verbatim Gateway via Modbus over RS232

Posted by dldaily on Fri, Feb 21, 2014 @ 7:55 AM

Demonstration of using Rockwell Automation's Integrated Architecture Builder to design an Allen-Bradley Micro800 PLC with an integrated and connected RACO Verbatim Gateway via Modbus over RS232 alarm monitoring and reporting system.... Continue Reading

Continue ReadingLeave a Comment Share This

Tip of the Month: Integrating MicroLogix to Catalyst via Modbus Protocol Over RS485

Posted by jBrown on Tue, Jul 26, 2011 @ 7:23 AM

When setting up the Modbus RTU Master/Slave over an RS485 network, a three-wire cable is required to connect back to the interface converter. The Simple NULL Modem cable with external +24 vdc power is recommended, but the Allen-Bradley 1761-CBL cable is also functional. To begin, plug the cable to the round eight-pin mini DIN receptacle and set the P10 Jumpers for RS-485 on the Catalyst. Parametric changes are also required within the RSLogix 500 and Alarmware to synchronize the Modbus Drivers. Here are the steps: 1. Connect the MicroLogix to your PC using the required 1761-CBL cable ... Continue Reading

Continue ReadingLeave a Comment Share This

Tip of the Month: Integrating MicroLogix to Verbatim Gateway via Modbus Protocol over RS232

Posted by jBrown on Tue, Jul 12, 2011 @ 4:20 AM

The Verbatim Gateway system—interfaced with an Allen-Bradley MicroLogix family of PLCs containing a native Modbus RTU Slave driver—performs alarm and monitoring functions with existing wiring to PLCs as inputs via data communications. In order to facilitate data communications via Modbus RTU Master/Slave over RS232 data interface, RACO provides a NULL Modem serial cable, VAB-1. This cable has the RJ-45 connector required for the system. Below are instructions on how to integrate MicroLogix to Verbatim Gateway via Modbus Protocol over RS232. Communication setup for Allen-Bradley Mi... Continue Reading

Continue ReadingLeave a Comment Share This

Tip of the Month: Integrating RACO Catalyst with Micrologix PLCs

Posted by jBrown on Thu, Mar 24, 2011 @ 11:27 PM

Interfacing RACO’s Catalyst  system with Allen-Bradley’s MicroLogix PLCs allows Catalyst to use existing wiring for alarm notifications and data logging. The following tips will get you started: 1. Assemble your components: For proper setup, you will need RACO’s Catalyst system and Alarmware software, Allen-Bradley’s MicroLogix PLC and RSLogix software and the coordinating cables from each company. 2. Set up MicroLogix communications: Connect MicroLogix to your PC with the cable, then launch the RSLogix software. Using the software, set the communications driver to Modbus RTU sl... Continue Reading

Continue ReadingLeave a Comment Share This

Connecting the RACO Catalyst RTU to the Hach Water Distribution Panel

Posted by jBrown on Tue, Jan 25, 2011 @ 12:20 PM

A RACO Catalyst remote telemetry unit (RTU)  is an ideal companion to a Hach Water Distribution Panel (WDP). With the right hardware and RACO Alarmware software, plus some easy-to-follow instructions, setting up the system is easy. Required Equipment A Hach WDP/Catalyst system involves connecting a Hach Mod I/O (#598000) to the WDP through an Aquatrend network cable (#5215700). The RTU communicates with the Mod I/O through an RS232 null modem cable. The RTU also is connected to a dedicated Plane Old Telephone System (POTS) with an RJ11 phone cord. The setup allows the Catalyst RTU to mo... Continue Reading

Continue ReadingLeave a Comment Share This